Representative specimens, simulating the performance of five conventional plywood floor systems, were tested under concentrated load in order to compare their performance with that stipulated by performance criteria developed on the basis of anticipated occupancy loads. In 24 out of 26 tests the performance of the specimens exceeded that required by the criteria. Data on failure loads, load-deflection characteristics and failure modes are presented and discussed.
A full-scale, first-story portion of a building system was tested in the laboratory in such a manner as to simulate the structural behavior of a three-story building under both service and potential ultimate loading conditions.Additional tests were performed on the system components to provide behavioral data needed for the evaluation of the system.Performance criteria for the evaluation of the structural safety and adequacy of certain building systems were developed.This report presents the results of the physical tests performed in the evaluation of the safety and structural adequacy of one such system, and discusses their significance.The report also presents data concerning the complex interaction between components which takes place in the building system.(Author).